Wellcome to our website!

010-624193092149659191

Oracle 服务器 X5-4

产品概述

Processor
Number 2 or 4 Processors
Architecture Type: Intel Xeon E7-8895 v3 Processors
CPUs Intel 2.6GHz 18-Core Xeon E7-8895 v3, 175W
Main Memory
Capacities
  • 2 Processor - Up to 48 DIMMs
  • 4 Processor - Up to 96 DIMMs
  • DIMM Size and Type: 16GB: DDR3L-1600/PC3L-12800 Registered DIMM or 32GB: DDR3L-1600/PC3L-12800 load-reduced DIMMs (LRDIMM)
  • 2 Processor - Minimum Memory Capacity: 128GB using 16GB DIMMs in 8 slots
  • 2 Processor - Maximum Memory Capacity: 1536GB using 32GB DIMMs in 48 slots
  • 4 Processor - Minimum Memory Capacity: 256GB using 16GB DIMMs in 16 slots
  • 4 Processor - Maximum Memory Capacity: 3072GB using 32GB DIMMs in 96 slots
Standard I/O
Network Four auto-negotiating 10 Gigabit Ethernet (GbE) ports (RJ-45 connector).
Network Management One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port.
USB Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports
Video One VGA 2D embedded graphics controller with DB-15 connector. Resolution: 1,600 x 1,200 x 16 bits @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
I/O Expansion Eleven PCI Express 3.0 Slots:
  • 9 slots are x8 PCIe slots (1 - 7, 9, & 10)
  • 2 slots are x16 PCIe slots (8 & 11)
  • 2 CPU processor configurations only support 6 PCIe slots, 1-6. Install order = 6, 4, 5, 3, 1
  • 4 CPU processor configurations support all 11 PCIe slots 1-11. Install order = 11, 8, 6, 4, 10, 7, 5, 3, 9, 1
  • PCIe slot 2 is reserved for the SAS HBA for the internal disk drives.
Internal Mass Storage
Disks Six front-accessible and hot-swappable 2.5" SAS-3 disk bays and optional DVD-RW drive. Up to four small form factor NVMe drives (6.4 TB total capacity). Four of the disk drive bays are predesignated as NVMe enabled and requires an Oracle NVMe enabling kit that consumes one PCIe slot. 

Drive Type Density Speed Form Factor
SAS-2 600GB 10,000 RPM 2.5"
SAS-2 1.2TB 10,000 RPM 2.5"
SAS-3 400GB Solid State 2.5"
NVMe PCIe 3.0 1.6TB Solid State 2.5"
Power Supplies and Fans
  • Two hot-swappable power supplies with N=N redundancy.
Environment
Power Consumption Online power calculator
AC power Operating input voltage range: 100 to 127 VAC (2-CPU configuration); 200 to 240 VAC (2-CPU or 4-CPU configuration)
Rated input current 100 to 127 VAC 12A and 200 to 240 VAC 10A.
Temperature Operating: 5° C to 35° C (41° F to 95° F) (sea level); 5° C to 31° C (41° F to 88° F) (at altitude)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Humidity Operating: 10% to 90% relative humidity noncondensing. 
Nonoperating: Up to 93% relative humidity noncondensing
Altitude Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft), except in China where regulations might limit installations to a maximum of 2000 m (6562 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Maximum Power Consumption 2000W
Maximum Heat Output 6824 BTU/hr
Acoustic Noise LwAd: 8.9 B (idle and operating, room temp.), 8.9 B (max. ambient); LpAm: 75 dBA (bystander position,
max. ambient)
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences.
EMC Emissions: FCC 47 CFR Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3.
Immunity EM55024
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • MSIP (Korea)
  • VCCI (Japan)
European Union Directives
  • 2014/35/EU Low Voltage Directive
  • 2014/30/EU EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weight
Height 129.9 mm (5.1 in.)
Width 436.5 mm (17.2 in.)
Depth 732 mm (28.8 in.)
752.35 mm (29.6 in) with PSU ejectors
Weight Maximum: 40 kg (88 lbs.)
Rack Mounting
Clearances Front: 1232 mm (48.5 in)
Rear: 914 mm (36 in)
Oracle Server X5-4 Racks
  • Sun Rack II 1042
  • Sun Rack II 1242
  • Tooless rackmounting slide rail kit.
  • Cable management arm.

   

 
 
 

北京微芯合创科技有限公司

地址 :     北京市朝阳区大郊亭中街华腾国际1号楼11C
电话 :     010-62419309
Q Q :     2149659191
邮编 :     100124